DTM-FAB

Specifications

Model DTM-EA DTM-EA/H DTM-ED
Sensitivity
selection
HIGH ±5μm (Graduation 0.2μm) ±2.5μm (Graduation 0.1μm) ±199.9μm, Resolution 0.1μm
MED ±25μm (Graduation 1μm) ±25μm (Graduation1μm)
LOW ±125μm (Graduation 5μm) ±125μm (Graduation 5μm) ±1999μm, Resolution 1μm
Indication error HIGH: Within ±1 graduation MED/LOW: Within ±1/2 graduation ±1%rdg±1 digit*1
Zero point
adjusting range
±50μm or more
Display 3 digits in LED display
and polarity (-)
Response speed (Pointer) Approx. 0.5 sec/full scale Approx. 400ms (max)
Analog output (Pointer) Approx. 0.5 sec/full scale DC±1V/full scale*2
Accuracy
guaranteed
temperature range
24°C±5°C
Operating
temperature
0°C ~ 50°C
Power supply AC100 ~ 240V±10% 50/60Hz Approx. 4VA *3 AC100 ~ 240V±10% 50/60Hz Approx. 5VA *3
Outside dimensions 110(W) x 175(D) x 185(H) mm
Weight Approx. 1.4kg

*1 Performance assurance range: ±99.9 μm when selected HIGH and ±999 μm when selected LOW. Note that the assurance differs depending on display selection and indication error.
*2 DC±1V is the output at ±100.0 μm when selected HIGH and ±1000 μm when selected LOW.
*3 The power cable attached to the unit has a rating of 125 V/10 A. If using it with a voltage other than this, prepare a high-voltage cable suited to the rating.